Case study: a food factory where the plant room was the hotspot

A real, anonymised assessment of a chilled-food factory — where the biggest hearing risk was the refrigeration plant, not the production line.

Impact Acoustics · updated 10 Aug 2026 · 5 min read
A real assessment, anonymised. The figures below are the actual measured results from a Noise at Work Assessment Impact Acoustics carried out in March 2026. The client and site are kept anonymous because the report is confidential; we can name them only with their written consent.

The site

A chilled- and frozen-food manufacturer in Cornwall, with Tetra Pak filling lines, a spiral freezer, a mix plant and an ammonia refrigeration plant serving the site. We assessed ten task and area positions on an 8-hour basis, from the factory floor to the plant rooms.

What we found

5060708090100LEP,d dB(A)Lower action value 80Upper action value 85Limit value 8793.9Ammonia plant87.9Compressor shed85.7Mix plant84.9Tetra Pak fillers82.5Spiral freezer82.4Line 181.0Line 278.9Packing74.1Goods intake
Real measured daily personal noise exposure (LEP,d) by work area, from an anonymised recent assessment. Bars above the red line are Hearing Protection Zones.

The three loudest positions were all services plant, not the production line: the ammonia refrigeration plant at 93.9 dB(A), the compressor shed at 87.9 and the mix plant at 85.7 — all at or above the upper action value. The Tetra Pak fillers and both production lines sat in the 81–85 dB(A) band, and goods intake was below the lower action value. No peak reached the 135 dB(C) action value.

The insight that pays for the survey

Two things surprised the site. First, the biggest hearing risk wasn't on the busy factory floor at all — it was in the refrigeration plant, where the daily dose is so high that a worker reaches the 85 dB(A) upper action value in about an hour of an eight-hour shift, so even short maintenance visits need protection. Second, the loudest single noise on site — a 114 dB(C) peak — was recorded in Packing, which has the site's lowest daily exposure at 78.9 dB(A). It's a clean illustration of why a walk-round ‘that sounds loud’ is no substitute for measurement: the area that startles you isn't always the one damaging hearing over a full day.

What the client got

That is the difference between a survey that just says “you're over the limit” and one that tells you exactly where to act — and keeps it current, which is what the 4-Year Care Plan is for.